Prius Healthcare Salute RDX Mattress System

Prius Healthcare Salute RDX Mattress System

Brand/Manufacturer: PRIUS HEALTHCARE USA
Save

Prius Healthcare Salute RDX Mattress System features an alternating pressure therapy with micro low air loss to aid patients who are at risk of developing pressure ulcers or have existing stage 1, 2, 3, or 4 ulcers. This mattress system is a therapeutic surface solution for any clinical care setting. Its eight-inch cell-in-cell flotation technology maintains a generous flow of dry air beneath the patient to enhance both the prevention and the healing of wounds.

Prius Healthcare Salute RDX Highlights

  • Happy Heel Control
  • Effective micro low air loss for moisture management
  • Nylon covered bottom cover for friction and noise reduction
  • Cable management system keeps electrical cables off the floor
  • CPR quick release system deflates the system within 20 seconds

Item # Desc Pkg Price
PHR-SALDXQ Salute RDX Mattress System Each
$2098.55
$1614.29

Prius Healthcare Salute RDX Features

  • Interchangeable air cell design provides easy cleaning and minimizes the proliferation of bacteria
  • The Salute RDX employs 8" air bladders with cell in cell design (4.5" of therapy, 3.5" of static air), to provide therapeutic alternating pressure and also allow the mattress to stay inflated in a power outage
  • The Salute RDX replacement mattress can accommodate patient weights up to 500 lbs
  • Happy heel provides extra softness in the last 5 air cells to provide protection for patient''s fragile heels
  • Modular design ensures ease of use and cleaning
  • Allow for the mattress to stay inflated during power outages
  • Has 3-in-1 alternating pressure cycle covering 66% of user''s body
  • Mesh center strip keeps cells together and provides protection from slipping between cells in any position

How to use Prius Healthcare Salute RDX Mattress System?

  1. Remove the control unit from the box and hang it at the foot end of the bed using the hooks on the back of the control unit.
  2. Plug the power cord into an appropriate outlet.
  3. If applicable remove the existing mattress from the bed frame.
  4. Remove the Salute RDX replacement mattress from its packaging and place it directly on the bed frame.
  5. Make sure that the connecting hose is positioned at the foot of the bed near the control unit.
  6. Secure the mattress to the bed frame using the straps on the bottom of the replacement mattress to prevent it from moving.
  7. Connect the mattress hose connector to the control unit. Make sure the connection is secure.
  8. Check the CPR valve to make sure it is set in the“Close” position.
  9. Turn on the control unit using the power switch located on the side of the unit. Select the auto firm comfort control dial for quick inflation. 
  10. During the inflation process, the low pressure LED will be displayed until the mattress is properly inflated, The inflation time of the mattress can take 30 to 40 minutes. 
  11. When the mattress is fully inflated, set the dial in accordance with the patient’s size and weight.
    - Run the system check
    - The system is ready for use.
    - Now the patient can be transferred onto the mattress.

Cleaning The MattressThe mattress should be cleaned weekly using a damp soft cloth and mild detergent. If the top cover or base cover becomes excessively soiled, put on clean gloves, plastic gown, and eye protection and remove top and base covers from the air cells and tubing. Place soiled covers in an appropriate container in accordance with your facilities standard operating procedures for contaminated waste, replace mattress with clean covers.

Storage and Care - Master Control Unit



  • Check the power cord and plug for abrasions or excessive wear
  • Plug in the control unit and verify air flows from the units hose connection ports
  • Place in plastic bag for storage

Overlay Mattress



  • Check the air manifold for kinks or breaks and replace if necessary
  • Turn the CPR valve to the open position and disconnect the air tubes from the control unit to allow the mattress to quickly deflate. Starting at the head end of the mattress roll the unit up and use the base mount straps to secure
  • Place mattress in a plastic bag of storage

Prius Healthcare Salute RDX Mattress System User manual


Specification

Mattress Specifications Values
Dimension (L) 80" x (W)36" x (H)10"
Weight 25.3 lbs
Weight Capacity 500 lbs
Cell Material Blue Nylon with PU Coating
Cell Number 18 cells
Cover Material Blue Nylon with PU coating finish
Base Material Black Polyester with PVC Coating
Master Control Unit Values
Dimensions (L)13.5" x (W)7.3" x (H)8.3"
Weight 7.1 lbs
Rating Voltage 110-120 volts
Max Current 0.2A max.
Rating Frequency 60Hz
Cycle Time 5, 10, 15, 20 mins
Alteration Type 3 in 1 alternation
Min/Max Pressure 12-47 mmHg +/- 6 mmHg
Air flow rate 6 liters per minute
Protection Type Class I, Type BF
Low-Pressure Alarm Visual / Audio
Power Failure Alarm Visual / Audio

 

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.rehab-store.com

Close