Drive Med-Aire Alternating Mattress Pressure Pump

Drive Med-Aire Alternating Mattress Pressure Pump

Brand/Manufacturer: DRIVE MEDICAL
Save
Authorized Retailer Badge

Drive Med-Aire Alternating Mattress Pressure Pump is designed for use with Drive Med-Aire Alternating Mattress System with Low Air Loss. It enables easy support and continued function of the mattress. The pump offers easy mattress adjustment and inflation and provides reliable and comfortable pressure relief.

Item # Desc Pkg Price
14027P Pump Only Each
$505.94
$374.81

Mattress Air Pump Features

  • Power Switch
    - The switch is on the right side of the pump
    - Turn ON/OFF the power, the pump will start or stop operation
  • Pressure-adjust Knob
    Turn the soft or firm knob to set a comfortable pressure level
  • Normal Pressure Indicator
    A visible indicator (green) tells the pressure has reached a preset or user-defined level
  • Low Pressure Indicator
    A visible indicator (yellow or red) warns the pressure is below a preset or user-defined level
  • Alarm Reset
    - The audible/visible alarm turns on when the pressure is low
    - To mute the audible alarm, press the reset button. The visible alarm indicator will flash
    - Re-press the reset button to reactivate the alarm
  • Static or Alternating control
    Press to set the air mattress either in static mode or alternating mode

What to buy with Drive Medical Electric Pump


How to Install Air Pump for Mattress?


  • Step 1: Place the mattress flatly on the bed frame. The inflation tube should be towards the foot end so that it can be connected to the inflation nozzles on the pump.
  • Step 2: Now place a thin cotton sheet over the quilted mattress top cover.
  • Step 3: Hang the pump over the frame or board at the foot end of the bed using the hangers on the back of the pump. Make sure the pump is secured.
  • Step 4:
    Connect the inflation tubes from the mattress to the pump’s inflating nozzles. Make sure they are properly attached.
    Note: Make sure the air hoses are not kinked or tucked under the mattress. Also, check to ensure the CPR valve is properly attached.
  • Step 5:
    - Plug the power cord into an electrical outlet with grounded AC power.
    - The power cord has a grounding wire with a grounding pin.
    - This three-wire plug must be plugged properly into an outlet and grounded as shown in the figure in the Grounding Instructions section.
    Note: Before inserting the plug into the outlet, make sure the voltage is compatible. Also, make sure this product is well-grounded.
  • Step 6: Turn on the power by pressing the power switch on the right side of the pump. Proceed to the Operation section.
  • Step 7: Make sure to disconnect the pump by unplugging the power cord when it is not in use.

Mattress Pressure Pump Specifications

Particulars Specifications
Power 120 VAC
Frequency 60 HZ
Pressure Range 30 mmHg to 80 mmHg (inner pressure mattress)
Air Volume 8-LPM
Cycle Time 10 Minutes
Functions Static and Dynamic features
Power Cord Length 14.76 ft
Pump Dimensions 11"W, 8"H, 3.5"D
Maximum Current 0.5 Amps

 

Warranty

The pump has a 1-year warranty.

Customer Reviews