Bio Protech MAXTENS 1000 Analog Dual Channel TENS Unit

Bio Protech MAXTENS 1000 Analog Dual Channel TENS Unit

Brand/Manufacturer: BIO PROTECH
Save
  • FSA Approved

Bio Protech TENS 1000 Pain Control Device offers a large variety of output combinations. The user can choose the setting that's best for them, with times ranging from 15 or 30 minutes to continuous mode. Three additional modes are available on MAXTENS 1000 Analog TENS: B (Burst), N (Normal), and M. (Modulation). To minimize acute aches from an accident or persistent illnesses like arthritis or other joint and muscle problems, the pulse rate, pulse width, and pulse amplitude are all adjustable.

Why choose Bio Protech TENS 1000 Pain Control Device?

  • Adjustable Impulses
  • Non-Invasive Option
  • ​Simple knobs to adjust the settings easily
  • Strongly built and looks nice
  • Zero Start feature for safety
  • Prevents accidental setting changes

Item # Desc Pkg Price
MAXTENS1K MAXTENS 1000 TENS Unit 5/Pack
$192.66
$142.75

Bio Protech TENS 1000 Features

  • MAXTENS 1000 is a battery operated pulse generator that sends electrical impulses to the body which reach the nerves causing pain.

  • The device is provided with two controllable output channels, each independent of each other. An electrode pair can be connected to each output channel

  • The electronics of the MAXTENS 1000 create electrical impulses whose intensity, duration, number per second and modulation my be altered with the controls or switches

  • Dial controls are very easy to use and the slide cover prevents accidental changes in the setting
MAXTENS 1000 TENS Unit Construction
 

When to use Bio Protech TENS 1000 Pain Control Device?

MAXTENS 1000 is used for the symptomatic relief and management of chronic intractable pain and adjunctive treatment of post-surgical or post-traumatic acute pain. This is a prescription device and should be used under continued medical supervision.

What does the Bio Protech/MAXTENS 1000 TENS Unit Include?

  • (1) TENS Unit
  • (4) TENS Electrode
  • (2) Leadwires
  • (1) 9V Battery, type 6F22
  • (1) Instruction Manual
  • (1) Carrying Case

Frequently Bought Together


How to use Bio Protech TENS 1000 Pain Control Device?

  1. Slide Cover: A slide-on panel cover covers the controls for Pulse Width. Pulse Rate. Mode Selector and Modulation Selector. Your medical professional may wish to set these controls for you and request that you leave the cover in place.
  2. Display LED: Each of the LEDs illuminates whenever the electronics of the device create a current impulse. Due to the capacity of the human eye, the illumination of the lamp can only be recognized up to a frequency of approximately 30 Hz. At higher frequencies, the lamp will appear to be constantly illuminated.
  3. On/Off Switch and Intensity Control: If both controls are in the off-position the device is switched off.
MAXTENS-1000 TENS Unit
 
  1. Lead Connector: The connection of the electrodes is made with a two-lead connector. The device must be switched off before connecting the cables. Both intensity controls must be at the off position. Electrodes must be pressed firmly on the skin.
Bio Protech MAXTENS1000
 
  1. Mode Control: Expose the controls by sliding the front cover down from the top of the unit. This switch has 3 positions: B for Burst stimulation. N for Constant stimulation. and M for modulation stimulation. Push the Mode Selector until engaged in the position desired.
MAXTENS-1000 Dual Channel TENS Unit
 
  1. Pulse Rate Control: This dial determines how many electrical impulses are applied through the skin each second. By turning these controls, the number of current impulses per second(Hz) for both channels can be continually adjusted. Unless otherwise instructed. turn the pulse rate control to the 2-150 Hz range.
MAXTENS1000 Analog Dual Channel TENS Unit
 
  1. Pulse Width Control: This dial adjusts the length of time each electrical signal is applied through the skin, which controls the strength and sensation of the stimulation.
MAXTENS1000 Analog Dual Channel TENS Unit
 
  1. Timer Control: The treatment time of TENS can be preset with Timer Control. This switch has 3 positions, 15, 30, and C (Continue). Push the Timer Control Until engaged in the position desired.
MAXTENS1000 Analog Dual Channel TENS Unit
 
  1. Check/Replace the Battery: Over time, in order to ensure the functional safety of TENS, changing the battery Is necessary.
    1. Make sure that both intensity controls are switched to the off position.
    2. Slide the battery compartment cover and remove it.
    3. Remove the battery from the compartment.
    4. Insert the battery into the compartment. Note the polarity indicated on the battery and in the compartment
    5. Replace the battery compartment cover and slide it close
    6. If the output adjust is not set to "0" while the battery is being connected. Prostim unit will not operate.

How to maintain and store MAXTENS 1000 Analog TENS Unit?

  1. The non-flammable cleaning solution is suitable for cleaning the device. Note: Do not smoke or work with open lights (for example. candles. etc.) when working with flammable liquids.
  2. Stains and spots can be removed with a cleaning agent.
  3. Do not submerge the device in liquids or expose it to large amounts of water.
  4. Return the device to the carrying box with sponge foam to ensure that the unit is well-protected before transportation.
  5. If the device is not to be used for a long period of time. remove the batteries from the battery compartment (acid may leak from used batteries and damage the device). Put the device and accessories in the carrying box and keep it in a cool dry place.
  6. The packed TENS device should be stored and transported under the temperature range of - 20t — +60-C, relative humidity 20% — 95%, atmosphere pressure 500 hPa 1060hPa.

MAXTENS-1000 User Manual

Precautions:

  • TENS is not effective for pain of central origin (This includes headache)
  • TENS devices have no curative value
  • Keep the device out of reach of children
  • Long-term stimulation at the same electrode site may cause skin irritation
  • Effectiveness is highly dependent upon patient selection by a person qualified in the management of pain patients
  • Simultaneous connection of a patient to an HF SURGICAL EQUIPMENT may result in burns at the site of the stimulator electrodes and possible damage to the stimulator
  • Operation in close proximity (e.g. 1m) to a shortwave or microwave therapy equipment may produce instability in the stimulator output
  • Remove batteries if the unit is not used for a long period of time
  • Never apply electrodes over irritated or broken skin

Contraindications:

  • If you have a demand—type cardiac pacemaker. do not use a TENS unit
  • Do not use TENS on the carotid sinus (neck) region
  • Do not use TENS for patients with known myocardial disease or arrhythmias without consultation and evaluation by a physician
  • Do not apply TENS for undiagnosed pain syndromes until etiology is established
  • Do not place electrodes on the site that may cause current to flow trans cerebrally (through the head)

Indications

  • Post-Surgery
  • Post-Trauma or Accident
  • Arthritis
  • Joint or Muscle Conditions
  • Alternative to Prescription Drugs

Specifications of Bio Protech MAXTENS 1000 TENS Unit

Particulars Specifications
Channel Dual
Amplitude Adjustable, 0-80mA peak into 500 ohm load each channel
Pulse Rate Adjustable, 2 ~ 150 Hz
Pulse Width Adjustable, 30 ~ 260 us
Mode B : Burst mode
N : Normal(constant) mode
M : Modulation mode
Wave Form Asymmetrical biphasic pulse
Timer 15, 30, continue
Power Supply 9V Battery
Size 105mm(H) x 70mm(W) x 24mm(T)
Weight 127g (battery included)

 

MAXTENS 1000 Warranty

MAXTENS 1000 carry a warranty of one year from the date of delivery.

 

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.rehab-store.com

Close